Tag Archives: Cummins Inline 6

Cummins Inline 6 Software Driver Pinout All Details

Cummins Inline 6 data link:
The INLINE 6 is a highly reliable data link adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software.
Cummins Inline 6 for sale:
cummins-inline6
Cummins Inline 6 price:
219 usd (27% off)
Cummins Inline 6 software download:
Cummins Inline 6 driver:
How to Install the INLINE 6 software driver:
  • Insert the INLINE 6 driver CD into your computer’s CD-ROM drive.
  • Run INLINE6_Driver_Setup.exe
  • If a Windows Explorer folder opens, select INLINE6_Driver_Setup.exe
Note that on some systems the autorun settings may be set to have the installation
to just begin executing upon CD insertion.
IF YOU SEE:
o WINDOWS XP – A message appear stating “The software you are installing has
not passed Windows Logo…” Click on”Continue Anyway”. Click on”Finish” when
installation is complete.
Cummins Inline 6 reflash:
Download the appropriate INLINE 6 zip file by clicking on a link above (note that unless you have a 64-bit Operating System, you should use the 32-bit file).
Unzip and extract the executable file using zip/unzip software.
Click on the Windows Start menu and click Run.
Click on the Browse button and locate the file you have downloaded.
Click the OK button to install the latest INLINE 6 Driver, reflash utility, and firmware on your PC.
Follow the onscreen instructions to complete the installation.
Connect +8 V to +50 V power to your INLINE 6 adapter through the DB25 cable you have.
Use your DB9F to DB9M serial cable or USB cable to connect the INLINE 6 adapter to the proper PC communication port.
Follow the Driver Installation and other instructions
Cummins has introduced a new data link adapter that is fully compliant with TMC’s RP1210 standard, and has been designed and environmentally tested to Cummins standards to be rugged and reliable.
Cummins Inline6 diesel engine:
Cummins has become the innovator and technology leader in data link adapters and service tools for diesel engines.
Cummins Inline 6 running with Insite 7.62 works perfect for diesel engines.
Cummins Inline 6 compatibility:
INLINE 5 and 6 is compatible with both PowerSpec and Insite.
PowerSpec versions of 4.2 and later support the RP1210 protocol and are thus compatible with the INLINE 6 and INLINE 5 adapters. See the chart below for an example of the basic connections needed to hook-up to the vehicle data link.
INSITE versions of 7.5 and later are compatible with the INLINE 6 and INLINE 5. Note that INSITE versions earlier than this are not fully RP1210B compliant and may not work with these adapters. See the chart below for an example of the basic connections needed to hook-up to the vehicle data link.
cummins-inline-6-connection
Cummins Inline 6 pinout:
Cummins Inline 6 is capable of autodetecting between CAN
(SAE J1939, SAE J2534 & ISO 15765/UDS) data rates of 250 kB or 500 kB.
Connections are simple with a standard USB interface that provides power to the unit.
A dual CAN channel allows connection to multiple Electronic Control Modules on the same vehicle for increased productivity and support.
Note that you cannot use inline 5 cable for inline 6 adapter …. because inline 6 cable has 2 additional pins
CAN2 High (+) H – 13
CAN2 Low (-) J – 17
Cummins Inline 6 data link adapter user manual:
http://blog.obdii365.com/2018/04/19/cummins-inline-6-software-driver-engine-pinout-all-details/

How to Set up Cummins Insite 7.6.2 on VMware

This is a how-to’s of Cummins 7.62 Inline Reader 5 or 6 installation on virtual machine.

 

If I buy an Inline 5 or 6 adaptor kit, is the insight software is on this CD as well?

 

The CD with software it’s usually included, and shipped together with a Cummins Inline Reader 5 or 6 data link adapter. Look here:

INLINE 5 Insite 7.62
INLINE 6 Insite 7.62

 

Which Windows version should I use with a virtual machine?

 

You can always use a virtual machine to run any version of windows you may need. But I think I heard guys running INSITE 7.6 on windows 10.

 

How to setup and install Insite 7.6.2 on Windows vitual machine?

 

Your Virtual Machine is also known as Compatibility mode in Windows. Before you click on the Install .exe for your program, simply right click the Icon, go to properties, then compatibility and click on run this in compatibility mode and select the operating system you want to run it under.

Cummins Insite 7.6.2 like windows XP or 7 but this will not guarantee it will work I’ve had issues with Ca1t3rm not responding to this at all. So the best bet is what experienced users suggested and buying a windows xp or windows 7 (32 bit) machine and dedicating to truck diagnostics only. NOTHING ELSE. It is now a tool that belongs to your truck. If you don’t treat it that way you run the risk of corrupting programs, files, virus’s, Malware, anything and everything that the wild world web will throw at it. You can also install OEM diagnostic programs for Volvo, International, ABS etc… on this machine. I haven’t found an OEM program that Windows 7 (32 bit) won’t run

You can easily build and have built for you really strong machines being these older windows platforms are cheap. I recommend a Panasonic Toughbook just for the durability of taking a beating and it’s handy dandy carrying handle (it makes me feel professional when I’m all covered in dirt in my 3 piece overalls)

insite-cummins-vitual-machine-install

The last – another important note you’d better read:

The site http://blog.obdii365.com/2018/03/08/why-buy-cummins-insite-7-62-instead-of-insite-8-xx/talking about Why did I buy Cummins Insite 7.62 instead of Insite 8.xx?

 

Hope this helps you all.

http://blog.obdii365.com/2018/03/25/install-cummins-inline-6-insite-7-62-on-virtual-machine/

insite-cummins-vitual-machine-install6

Cummins Insite 8.2.0.184 Installation and Activation

Here are the step-by-step guides on installing & activating Cummins Insite 8.2.0.184 Pro version and Lite (Count) version on Windows 10 (including patch download).
Software version: 8.2.0.184
cummins-insite-820-1
cummins-insite-820-2
Difference between insite 8.2 Pro version and Lite Version:
Pro version including all function of Lite version, and also including Automotive Calibrations Data Cummins INCAL and Reflash ECU data, read & write ECU
Multi-language available: English(united states)/Chinese(simplified)/Danish/Dutch/Finnish/French/German/Italian/Japanese/Korean/Norwegian/Portuguese/Russian/Spanish/Swedish/Turkish
Compatible truck diagnostic tools:
1.Cummins INLINE 6 Data Link Adapter
2.Cummins INLINE 5 Data Link Adapter
3.DPA5 Dearborn Protocol Adapter 5 Heavy Duty Truck Scanner
4.NEXIQ USB Link
5.XTruck USB Link
6.AUGOCOM H8 Truck Diagnostic Tool
How to Install & Activation Cummins INSITE 8.2.0 Lite (Count) version?
How to Install & Activation Cummins INSITE 8.2.0 Pro version?
Operating system: Windows 7-Windows 10
Windows 10 you should disable anti-virus program and run software as administrator. 

Part 1: Install & Activate Cummins INSITE 8.2.0 Lite version

First you need to download patch for Lite version
Step 1: Install INSITE 820 Lite software
Open software folder
install-insite-820-lite-version-1
Extract INSITE8.20.184 zip file to desktop
Open INSITE8.20.184 folder
install-insite-820-lite-version-2
Open autorun
install-insite-820-lite-version-3
install-insite-820-lite-version-4
install-insite-820-lite-version-5
Select Manual Install Options->Required Installs->Install INSITE
install-insite-820-lite-version-6
Select INSITE language
Install Microsoft.NET Framework 4.5 Full
install-insite-820-lite-version-7
Install INSITE Data Pack
install-insite-820-lite-version-8
Accept INSITE Data Pack license agreement
Click Next
install-insite-820-lite-version-9
Finish Install data pack
install-insite-820-lite-version-10
Install INSITE CSS Service
Click Next
install-insite-820-lite-version-11
Verify PC date and time.
INSITE contains features which are dependent upon an accurete PC date and time. Please verify that
the date and time settings are correct before continuing the installation.
Tick “I have verified hat the date and time settings are correct”
Click Next
Accept license agreement
Click Install
install-insite-820-lite-version-12
Finish install INSITE software
This will generate Cummins INSITE software on desktop
Step 2: Activate INSITE 8.2 Lite version
Run Cummins INSITE software as administrator (very important)
Accept 2 license agreements
install-insite-820-lite-version-13
Select Simulator Mode
Exit INSITE software
install-insite-820-lite-version-14
Delete all files on desktop
install-insite-820-lite-version-15
Download INSITE 820 Count patch above and paste it to desktop
install-insite-820-lite-version-16
Run “820 Count” file and send the SN (hardware ID) to your dealer
install-insite-820-lite-version-17
Dealer will send you user name and activation key
install-insite-820-lite-version-18
Enter user name and activate here
Click on Register
install-insite-820-lite-version-19
Registration success. Now you can use Cummins Insite Lite version.

Part II: Install & Activate Cummins INSITE 8.2.0 Pro version

First you need to download patch for activation as well
Step 1: Install INSITE Pro software
Extract INSITE8.20.184 pro zip file to desktop
Open INSITE8.20.184 folder
Open autorun
Select Manual Install Options->Required Installs->Install INSITE
Select INSITE language
Install Microsoft.NET Framework 4.5 Full
Install INSITE Data Pack
Accept INSITE Data Pack license agreement
Click Next
Finish Install wizard
Install INSITE CSS Service
Click Next
Click Next
Verify PC date and time.
INSITE contains features which are dependent upon an accurete PC date and time. Please verify that
the date and time settings are correct before continuing the installation.
Tick “I have verified hat the date and time settings are correct”
Click Next
Accept license agreement
Click Install
Finish install INSITE software
Step 2: Activate INSITE 8.2.0 Pro verison
Run Cummins INSITE software as administrator (very important)
Accept 2 license agreements
Select Simulator Mode
Exit INSITE sofware
Delete all files on desktop
install-insite-820-pro-1
Download Cummins INSITE 8.2.0 pro pacth and paste it on desktop
install-insite-820-pro-2
Run “820 Pro” file and send the SN to the dealer
install-insite-820-pro-3
Dealer will send you User name and register key
install-insite-820-pro-4
Paste user name and register key here.
Now you have activated the INSITE Pro software.
Start using the software.

How to use Cummins Insite 8.1 for ECM Programming

Cummins insite training: How to program Volvo, Cummins, CAT ECM with Cummins Insite heavy duty diagnostic software? Here you go.

 

Tools required:

Software: Cummins Insite Pro software

Hardware options: Cummins Inline 6 data link, Nexiq/VXTRUCK adapter or DPA5 truck scanner

 

 

 

(Safe) Cummins insite crack 8.1: 100% tested & works good

http://www.obdii365.com/wholesale/cummins-insite-software-pro-version.html

cummins-insite-pro-8.1-download

cummins-insite-pro-8.1-download-1

cummins-insite-pro-8.1-download-2

cummins-insite-pro-8.1-download-3

It’s cummins insite pro, look here: (it’s about why you need INSITE PRO version instead of BASIC)

http://blog.obdii365.com/2017/05/17/cummins-insite-basic-vs-insite-lite-vs-insite-pro/

 

Now, we’ll go to program ECM with Cummins insite pro:

 

Connect truck scanner to the car with the 9pin to OBD2 cable

dpa5+cummins-insite-program-ecm-(1)

dpa5+cummins-insite-program-ecm-(2)

dpa5+cummins-insite-program-ecm-(3)

dpa5+cummins-insite-program-ecm-(4)

Connect DPA5 to the laptop with the USB cable

dpa5+cummins-insite-program-ecm-(5)

DPA5 is communicating…

dpa5+cummins-insite-program-ecm-(6)

Run Cummins insite software

dpa5+cummins-insite-program-ecm-(7)

Select DPA5 dual CAN

dpa5+cummins-insite-program-ecm-(8)

Connect to ECM

dpa5+cummins-insite-program-ecm-(9)

dpa5+cummins-insite-program-ecm-(10)

Fault codes

dpa5+cummins-insite-program-ecm-(11)

dpa5+cummins-insite-program-ecm-(12)

dpa5+cummins-insite-program-ecm-(13)

Work orders

dpa5+cummins-insite-program-ecm-(14)

dpa5+cummins-insite-program-ecm-(15)

New work orders

dpa5+cummins-insite-program-ecm-(16)

dpa5+cummins-insite-program-ecm-(17)

dpa5+cummins-insite-program-ecm-(18)

dpa5+cummins-insite-program-ecm-(19)

dpa5+cummins-insite-program-ecm-(20)

New ECM image

dpa5+cummins-insite-program-ecm-(21)

dpa5+cummins-insite-program-ecm-(22)

dpa5+cummins-insite-program-ecm-(23)

dpa5+cummins-insite-program-ecm-(24)

dpa5+cummins-insite-program-ecm-(25)

Disconnect from ECM

dpa5+cummins-insite-program-ecm-(26)

dpa5+cummins-insite-program-ecm-(27)

Close Cummins insite software

dpa5+cummins-insite-program-ecm-(28)

Job’s done!

 

www.obdii365.com

http://blog.obdii365.com/2017/11/01/use-cummins-insite-pro-for-ecm-programming/

How to solve Cummins Insite 8.1 ECM Connection Error 5204

Here you go… How to solve Cummins Insite 8.1 Connection Error 5204 5202 5201 5200

 

with DPA5 adapter, i try to connect with Cummins insite and i have error code 5204 or only no connection and not blinking the leds

 

This is the error 5204 popped up when connect Prostar 2005 with cummins engine:

ECM connection

Error number: 5204

 

Communication between the datalink adapter and the ECM could not be established.

 

Please check the following conditions:

The key switch is on

The cables are between the datalink and the ECM are properly connected

The cables are in good condition

The correct adapter type is selected

The correct communication protocol is selected

 

Select retry, cancel or help for additional troubleshooting steps

Cummins-insite-error-5204-web

Here is what have been tried but failed!

Try to connect whit J1939…..same issue

 

On truck does not even get the engine and the others only couple line and very slow, might be some thing with them trucks

 

some things odd2006 models connect through J1939 and works.
Tryed on 3 trucks already that are 2005 and older the connect thought J1708 it says engine 128
And when doing the J 1939 test on them it says something like data error

 

Check the driver is installed well

J1939 & J1708 are added to the software

 

Finally, SOLVED!

The solution is this, connect, then scan to diagnostic connector but not to USB, open the Cummins insite and push connect, when the Insite begin to connect, immediately connect the USB and ready….

 

 

 

The final tip- Error Messages for communication failures:

Error 5200: Indicates communication loss between computer and the datalink

adapter.

Error 5201: Indicates communication loss between the datalink adapter and the

ECM.

Error 5202: Indicates no communication could be established between the

datalink adapter and the computer.

Error 5204: Indicates no communication could be established between the

datalink adapter and the ECM.

If the “Auto Configure” and/or “Datalink Adapter Connection Test” do not find the adapter when connected, manually configure the Cummins Inline 6 Data link adapter connection.

http://blog.obdii365.com/2017/06/04/solved-cummins-insite-ecm-connection-error-5204/

 

www.hobdii.com